V-255570

CAT II (Medium)

The DBN-6300 must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC).

Rule ID

SV-255570r961443_rule

STIG

DBN-6300 NDM Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-001890

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.

Check Content

Verify the time zone is configured for "UTC".

Navigate to Settings >> Initial Configuration >> Time.

View the "Time Zone" box.

If the Time Zone is not set to "UTC", this is a finding.

Fix Text

Configure the time zone to "UTC".

Navigate to Settings >> Initial Configuration >> Time and click on "NTP".

Click on the drop-down box next to the "Time Zone" label.

Select "UTC" underneath the "Etc" category.

Click on "Commit".