STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to z/OS SRRAUDIT for ACF2 Security Technical Implementation Guide

V-224342

CAT II (Medium)

SRRAUDIT installation datasets must be properly protected.

Rule ID

SV-224342r1141639_rule

STIG

z/OS SRRAUDIT for ACF2 Security Technical Implementation Guide

Version

V7R2

CCIs

CCI-001499CCI-002234

Discussion

SRRAUDIT installation datasets have the ability to use privileged functions and/or have access to sensitive data. Failure to properly restrict access to these datasets could result in violating the integrity of the base product, which could result in compromising the operating system or sensitive data.

Check Content

Refer to the following report produced by the dataset and Resource Data Collection:

- SENSITVE.RPT(SRRPROD).

Automated Analysis
Refer to the following report produced by the dataset and Resource Data Collection:

- PDI(ZSRR0000).

Verify that the accesses to the SRRAUDIT installation datasets are properly restricted. If the following guidance is true, this is not a finding.
 
The ACF2 dataset rules for the datasets do not restrict READ access to systems programming personnel, domain level production control and scheduling personnel, security personnel, and auditors.

The ACF2 dataset rules for the datasets do not restrict WRITE and/or greater access to systems programming personnel.

The ACF2 dataset rules for the datasets do not specify that all (i.e., failures and successes) WRITE and/or greater access will be logged.

Fix Text

The ISSO will ensure WRITE and/or greater access to SRRAUDIT installation datasets is limited to systems programmers only, and all WRITE and/or greater access is logged. READ access can be given to security personnel, production control and scheduling personnel, and auditors. All failures and successful WRITE and/or greater accesses are logged.

The installing systems programmer will identify and document the product datasets, categorize them according to who will have WRITE and/or greater access, and if required, ensure that all WRITE and/or greater accesses are logged. The installing systems programmer will identify if any additional groups have WRITE and/or greater access for specific datasets, and once documented, will work with the ISSO to ensure they are properly restricted to the Access Control Program (ACP) active on the system.

(Note: The datasets and/or dataset prefixes identified below are examples of a possible installation. The actual datasets and/or prefixes are determined when the product is installed on a system through the product's installation guide and can be site specific.)

Datasets to be protected will be: 
SYS2.SRRAUDIT

The following commands are provided as a sample for implementing dataset controls: 

$KEY(SYS2)
SET RULE
$KEY(S2S)
$PREFIX(SYS2)
SRRAUDIT.- UID(audtaudt) R(A) E(A) DATA(DEFAULT Auditor)
SRRAUDIT.- UID(pcspaudt) R(A) E(A) DATA(DEFAULT Production control and Scheduling)
SRRAUDIT.- UID(secaaudt) R(A) E(A) DATA(DEFAULT Security)
SRRAUDIT.- UID(syspaudt) R(A) W(L) A(L) E(A) DATA(DEFAULT SYSPROG)
SRRAUDIT.- UID(tstcaudt) R(A) W(L) A(L) E(A) DATA(DEFAULT Trusted STCs)