STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to HYCU Protege Security Technical Implementation Guide

V-268240

CAT II (Medium)

The HYCU virtual appliance must generate audit records when successful/unsuccessful attempts to delete administrator privileges occur.

Rule ID

SV-268240r1038772_rule

STIG

HYCU Protege Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-000172

Discussion

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. Audit records can be generated from various components within the network device (e.g., module or policy filter).

Check Content

Check the contents of the "/var/log/audit/audit.log" file.

HYCU also maintains Event (Audit) information in the "HYCU Web UI Events" menu.

Verify the audit log contains records showing successful/unsuccessful attempts to modify or delete administrator privileges.

If the audit log is not configured or does not have required contents, this is a finding.

Fix Text

Log in to the HYCU VM console and load the STIG audit rules by using the following commands:

1. cp /usr/share/audit/sample-rules/10-base-config.rules /usr/share/audit/sample-rules/30-stig.rules /usr/share/audit/sample-rules/31-privileged.rules /usr/share/audit/sample-rules/99-finalize.rules /etc/audit/rules.d/

2. augenrules --load