V-252188

CAT II (Medium)

The HPE Nimble must display the Standard Mandatory DoD Notice and Consent Banner before granting access to the device.

Rule ID

SV-252188r960843_rule

STIG

HPE Nimble Storage Array NDM Security Technical Implementation Guide

Version

V2R1

CCIs

CCI-000048

Discussion

Display of the DoD-approved use notification before granting access to the network device ensures privacy and security notification verbiage used is consistent with applicable federal laws, Executive Orders, directives, policies, regulations, standards, and guidance. System use notifications are required only for access via logon interfaces with human users.

Check Content

Attempt a login to NimOS by typing "ssh username@array", where username is a valid user, and array is an array DNS name. If the correct DoD banner is not displayed before a password prompt, this is a finding.

Fix Text

Type "group --edit --login_banner", and then copy-paste or type the required banner. Then, to display the banner before login, type "group --edit --login_banner_after_auth no".