STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to z/OS ROSCOE for ACF2 Security Technical Implementation Guide

V-224341

CAT II (Medium)

ROSCOE configuration/parameter values are not specified properly.

Rule ID

SV-224341r1141636_rule

STIG

z/OS ROSCOE for ACF2 Security Technical Implementation Guide

Version

V7R2

CCIs

CCI-000015CCI-000381

Discussion

Product configuration/parameters control the security and operational characteristics of products. If these parameter values are improperly specified, security and operational controls may be weakened. This exposure may threaten the availability of the product applications, and compromise the confidentiality of customer data.

Check Content

Have the product's systems programmer display the configuration/parameters control statements used in the current running product to define or enable security. This information is located in the SYSIN DD statement in the JCL of the STC/Batch job.

Automated Analysis
Refer to the following report produced by the z/OS Data Collection:

- PDI(ZROS0040).

Verify the following specifications. This is not a finding.

Keyword	Value
EXTSEC	ACF2
ACFEXT	YES
CLLEXT	YES
JOBEXT	YES
LIBEXT	YES
MONEXT	YES
PRVEXT	YES
RPFEXT	YES
UPSEXT	YES

If the above is true, this is not a finding.

If the above is untrue, this is a finding.

Fix Text

The product systems programmer will verify that any configuration/parameters that are required to control the security of the product are properly configured and syntactically correct.
 
See the required parameters below: Example

Keyword	Value
EXTSEC	ACF2
ACFEXT	YES
CLLEXT	YES
JOBEXT	YES
LIBEXT	YES
MONEXT	YES
PRVEXT	YES
RPFEXT	YES
UPSEXT	YES