STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Microsoft Project 2016 Security Technical Implementation Guide

V-70727

CAT II (Medium)

Untrusted intranet zone access to Project servers must not be allowed.

Rule ID

SV-85351r1_rule

STIG

Microsoft Project 2016 Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-001170

Discussion

Allows users to access Project Server Web sites and Workspaces that have not been added to their trusted internet zones. If you enable this setting, users can access Project Server and Microsoft SharePoint Foundation sites that are not in their trusted internet zones. If this setting is disabled or not configured, users are required to add the Project Server and Microsoft SharePoint Foundation sites to their trusted internet site zones.

Check Content

Verify the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" is set to "Disabled". 

Procedure: Use the Windows Registry Editor to navigate to the following key: 

HKCU\Software\Policies\Microsoft\Office\16.0\ms project\security

Criteria: If the value TrustWSS is REG_DWORD = 0, this is not a finding.

Fix Text

Set the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2016 -> Project Options -> Security "Enable untrusted intranet zone access to Project server" to "Disabled".