STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Cisco NX OS Switch NDM Security Technical Implementation Guide

V-220499

CAT II (Medium)

The Cisco switch must be configured to record time stamps for log records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Rule ID

SV-220499r961443_rule

STIG

Cisco NX OS Switch NDM Security Technical Implementation Guide

Version

V3R6

CCIs

CCI-001890

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

Check Content

Review the Cisco switch configuration to verify that it is compliant with this requirement as shown in the example below:

clock timezone EST -5 0

Note: UTC is the default; hence, the command set time-zone may not be seen in the configuration. This can be verified using the show system uptime command.

If the switch is not configured to record time stamps for log records that can be mapped to UTC or GMT, this is a finding.

Fix Text

Configure the Cisco switch to record time stamps for audit records that can be mapped to UTC or GMT as shown in the example below:

SW1(config)# clock timezone EST -5 0