STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to RUCKUS ICX NDM Security Technical Implementation Guide

V-273851

CAT II (Medium)

The RUCKUS ICX device must be configured to compare the internal system clocks on an organization-defined frequency with two organization-defined authoritative time sources.

Rule ID

SV-273851r1110853_rule

STIG

RUCKUS ICX NDM Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-004923

Discussion

Synchronization of internal system clocks with an authoritative source provides uniformity of time stamps for systems with multiple system clocks and systems connected over a network.

Check Content

Verify NTP is configured and synchronizing with two peers:

device#show ntp association
address                                   Domain name                             Reference Clock  st  when  poll  Reach delay  offset   disp  
*~ 216.239.35.8                            None                                     GOOG             1    56    64   377 30.444   2.0021  2.884
+~ 23.150.40.242                         pool.ntp.org                         204.9.54.119     2    61    64   377 44.339  -0.6625  1.220
* synced, # selected, + candidate, - outlayer, x falseticker, ~ configured, **More characters in domain name

Fix Text

Configure NTP clock synchronization.

Configure NTP:
device#configure terminal
device(config)# ntp 
device(config-ntp)#server 216.239.35.8 (example IP)
device(config-ntp)# write memory

Configure NTP with authentication:
device#configure terminal
device(config)# ntp 
device(config-ntp)#server 216.239.35.8 (example IP)
device(config-ntp)#authentication-key key-id 1234 sha1 testntpsession
device(config-ntp)# write memory