V-245820

CAT II (Medium)

Information Security (INFOSEC) - Secure Room Storage Standards - Perimeter Construction using Proper Permanent Construction Materials for True Ceiling, Walls and Floors.

Rule ID

SV-245820r1138481_rule

STIG

Traditional Security Checklist

Version

V2R8

CCIs

None

Discussion

Failure to meet standards for ensuring that there is structural integrity of the physical Perimeter surrounding a secure room (AKA: collateral classified open storage area) could result in a lack of structural integrity and the undetected loss or compromise of classified material. Permanent construction materials; while not impenetrable, provide physical evidence of an attempted or actual intrusion into a secure room space. Construction materials and application techniques that are not permanent in nature can potentially be removed to allow for access to secure room space and then replaced by an intruder upon egress from the area. This effectively negates the detection capability afforded by permanent construction techniques and materials. Examples of non-permanent material would be modular walls that can be removed and replaced with ease or plywood board (or other materials) applied with screws or nails that can be removed from outside the secure room space and then replaced using common tools. REFERENCES: CJCSI 6510.01F, INFORMATION ASSURANCE (IA) AND SUPPORT TO COMPUTER NETWORK DEFENSE (CND), Enclosure C, paragraph 34. NIST Special Publication 800-53 (SP 800-53), Rev 4, Controls: MP-3, PE-3, PE-4, and PE-5. DOD Manual 5200.01, Volume 3, SUBJECT: DOD Information Security Program: Protection of Classified Information: Enclosure 3, paragraphs 3.a.(3) and 3.b.(1), (2) &(3); Appendix to Enclosure 3, paragraph 1.b.(1), (2) & (5). 32 CFR 117 and 32 CFR 2001 and 2003 as well as DOD Manual 5220.32 Volume 1

Check Content

For secure rooms or areas (*containing inspectable SIPRNet assets) check:

1. That walls, floor, and roof construction of secure rooms are made of permanent construction materials; i.e., plaster, gypsum wallboard, metal panels, hardboard, wood, plywood, or other materials offering resistance to, and evidence of unauthorized entry into the area. Materials such as plywood must be attached in a manner so as not to enable easy removal of screws or nails to gain ingress and then replace upon egress. 

2. The "True" ceiling shall be constructed of plaster, gypsum, wallboard material, hardware or any other acceptable material. 

TACTICAL ENVIRONMENT: This check is applicable where vaults or secure rooms are used to protect classified materials or systems. The only exception will be for urgent (short term) tactical operations or other contingency situations where fixed facilities and equipment are not yet present or incapable of being used.

Fix Text

1. Secure rooms or areas (*containing inspectable SIPRNet assets) must have walls, floor, and roof construction made of permanent construction materials; i.e., plaster, gypsum wallboard, metal panels, hardboard, wood, plywood, or other materials offering resistance to, and evidence of unauthorized entry into the area. 

2. Materials such as plywood must be attached in a manner so as not to enable easy removal of screws or nails to gain ingress and then replace upon egress. 

3. The "True" ceiling shall be constructed of plaster, gypsum, wallboard material, hardware or any other acceptable material.