STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Arista MLS EOS 4.2x NDM Security Technical Implementation Guide

V-255954

CAT II (Medium)

The Arista network device must enforce a minimum 15-character password length.

Rule ID

SV-255954r882204_rule

STIG

Arista MLS EOS 4.2x NDM Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-000205

Discussion

Password complexity, or strength, is a measure of the effectiveness of a password in resisting attempts at guessing and brute-force attacks. Password length is one factor of several that helps to determine strength and how long it takes to crack a password. The shorter the password, the lower the number of possible combinations that need to be tested before the password is compromised. Use of more characters in a password helps to exponentially increase the time and/or resources required to compromise the password.

Check Content

Review the Arista device configuration "show management security" to determine the minimum 15-character password length.

 switch#show run | section management security
management security
   password minimum length 15
!

If the Arista network device does not enforce a minimum 15-character password length, this is a finding.

Fix Text

Configure the Arista device to enforce a minimum password 15-character length.

 switch#configure
switch(config)#management security
switch(config-mgmt-security)#password minimum length 15
switch(config-mgmt-security)#exit
switch(config)#
!