STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to IBM AIX 7.x Security Technical Implementation Guide

V-215369

CAT II (Medium)

The daytime daemon must be disabled on AIX.

Rule ID

SV-215369r958478_rule

STIG

IBM AIX 7.x Security Technical Implementation Guide

Version

V3R2

CCIs

CCI-000381

Discussion

The daytime service provides the current date and time to other servers on a network. This daytime service is a defunct time service, typically used for testing purposes only. The service should be disabled as it can leave the system vulnerable to DoS ping attacks.

Check Content

From the command prompt, execute the following command: 
# grep "^daytime[[:blank:]]" /etc/inetd.conf

If there is any output from the command, this is a finding.

Fix Text

In "/etc/inetd.conf", comment out the "daytime" entries by running commands: 
# chsubserver -r inetd -C /etc/inetd.conf -d -v 'daytime' -p 'tcp' 
# chsubserver -r inetd -C /etc/inetd.conf -d -v 'daytime' -p 'udp'

Restart inetd:
# refresh -s inetd