STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

V-217362

CAT III (Low)

The Arista Multilayer Switch must generate audit records when successful/unsuccessful attempts to access privileges occur.

Rule ID

SV-217362r960885_rule

STIG

Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-000172

Discussion

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. Audit records can be generated from various components within the information system (e.g., module or policy filter).

Check Content

Review the switch configuration and verify that logging is enabled.

If logging is not enabled or is not enabled with sufficient detail to fulfill the specifications set forth in the VulDiscussion, this is a finding.

To determine if logging is enabled, enter: 

switch#show logging

The output must show logging as enabled, with a logging level of informational or debugging.

In order to ensure all user commands are captured, the following statement must be in the running config:

aaa accounting commands all default start-stop logging [group radius]

Fix Text

Enable logging on the switch with sufficient detail to fulfill the specifications set forth in the VulDiscussion.

To configure logging to a remote syslog server at the informational level, enter:

switch#config
switch(config)#logging host [ip address]
switch(config)#logging trap informational

Then configure the following AAA:

aaa accounting commands all default start-stop logging [group radius]