STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

V-217356

CAT II (Medium)

The Arista Multilayer Switch must automatically audit account creation.

Rule ID

SV-217356r960777_rule

STIG

Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-000018

Discussion

Upon gaining access to a network device, an attacker will often first attempt to create a persistent method of reestablishing access. One way to accomplish this is to create a new account. Notification of account creation helps to mitigate this risk. Auditing account creation provides the necessary reconciliation that account management procedures are being followed. Without this audit trail, personnel without the proper authorization may gain access to critical network nodes.

Check Content

Review the switch configuration and verify that logging is enabled.

If logging is not enabled or is not enabled with sufficient detail to fulfill the specifications set forth in the VulDiscussion, this is a finding.

To determine if logging is enabled, enter: 

switch#show logging

The output must show logging as enabled, with a logging level of informational or debugging.

In order to ensure all user commands are captured, the following statement must be in the running config:

aaa accounting commands all default start-stop logging [group radius]

Fix Text

Enable logging on the switch with sufficient detail to fulfill the specifications set forth in the VulDiscussion.

To configure logging to a remote syslog server at the informational level, enter:

switch#config
switch(config)#logging host [ip address]
switch(config)#logging trap informational

Then configure the following AAA:

aaa accounting commands all default start-stop logging [group radius]