V-205556

CAT II (Medium)

The Mainframe Product must provide an immediate real-time alert to the operations staff, system programmers, and/or security administrators, at a minimum, of all audit failure events requiring real-time alerts.

Rule ID

SV-205556r961401_rule

STIG

Mainframe Product Security Requirements Guide

Version

V3R4

CCIs

CCI-001858

Discussion

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected. Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).

Check Content

If the Mainframe Product does not perform audit data management or storage function, this is not applicable.

Examine configuration settings.

If the Mainframe Product does not provide for immediate real-time alerts to operations staff, system programmers, and/or security administrators for audit failures requiring real-time alerts, this is a finding.

Fix Text

Configure the Mainframe Product to provide for immediate real-time alerts to operations staff, system programmers, and/or security administrators for audit failures requiring real-time alerts.