Rule ID
SV-283778r1203581_rule
Version
V1R1
CCIs
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.
Verify a time zone is configured on the device, as shown in the example below: - show log log-id <log id> show log log-id 101 498 2025/11/10 18:35:48.230 UTC MINOR: USER #2011 management admin "User from 10.2.0.2: NFS-Sr-2s# configure log syslog 1" If the Nokia router does not record time stamps for audit records that can be mapped to UTC or GMT, this is a finding.
Configure the Nokia router to record time stamps for audit records that can be mapped to UTC or GMT using the commands below: - configure log log-id <log id> - time-format utc