STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to HP FlexFabric Switch NDM Security Technical Implementation Guide

V-230162

CAT II (Medium)

Upon successful logon, the HP FlexFabric Switch must notify the administrator of the date and time of the last logon.

Rule ID

SV-230162r961863_rule

STIG

HP FlexFabric Switch NDM Security Technical Implementation Guide

Version

V1R4

CCIs

CCI-000052CCI-000366

Discussion

Administrators need to be aware of activity that occurs regarding their network device management account. Providing administrators with information regarding the date and time of their last successful logon allows them to determine if any unauthorized activity has occurred. This incorporates all methods of logon, including, but not limited to, SSH, HTTP, HTTPS, and physical connectivity.

Check Content

Determine if the HP FlexFabric Switch is configured to notify the administrator of the date and time of their last logon. Once the logon credentials have been entered the system should display the previous logon information for the user:

Log on as: admin
admin@15.252.78.64's password:
Your logon failures since the last successful logon:
 Wed May 27 10:06:04 2015
 Wed May 27 10:06:09 2015

Last successfully logon time: Wed May 27 10:45:51 2015

If the administrator is not notified of the date and time of the last logon upon successful logon, this is a finding.

Fix Text

Configure the HP FlexFabric Switch to notify the administrator of the date and time of the last successful logon:

[HP]  password-control enable