STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Ivanti MobileIron Sentry 9.x NDM Security Technical Implementation Guide

V-250996

CAT I (High)

MobileIron Sentry must terminate all network connections associated with a device management session at the end of the session, or the session must be terminated after 10 minutes of inactivity except to fulfill documented and validated mission requirement.

Rule ID

SV-250996r802210_rule

STIG

Ivanti MobileIron Sentry 9.x NDM Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-001133

Discussion

Terminating an idle session within a short time period reduces the window of opportunity for unauthorized personnel to take control of a management session enabled on the console or console port that has been left unattended. In addition, quickly terminating an idle session will also free up resources committed by the managed network element. Terminating network connections associated with communications sessions includes, for example, de-allocating associated TCP/IP address/port pairs at the operating system level, or de-allocating networking assignments at the application level if multiple application sessions are using a single, operating system-level network connection. This does not mean that the device terminates all sessions or network access; it only ends the inactive session and releases the resources associated with that session.

Check Content

The MobileIron Sentry System Manager has two interfaces, a CLI restricted shell and web-based GUI. In the MobileIron Sentry MICS portal, verify that the MobileIron Sentry CLI timeout is set to 10 minutes.

1. Log in to MobileIron Sentry.
2. Go to Settings >> CLI.
3. Within CLI Configuration, verify the CLI Session Timeout(minutes) is set to greater than 10 minutes.

If the CLI Session Timeout(minutes) is not set to greater than 10 minutes, this is a finding.

Fix Text

Configure the Sentry to terminate the connection associated with a device management session at the end of the session or after 10 minutes of inactivity.

1. Log in to MobileIron Sentry.
2. Go to Settings >> CLI.
3. Within CLI Configuration, input "10" for CLI Session Timeout(minutes).