V-206687

CAT II (Medium)

The firewall must protect the traffic log from unauthorized modification of local log records.

Rule ID

SV-206687r604133_rule

STIG

Firewall Security Requirements Guide

Version

V3R3

CCIs

CCI-000163

Discussion

If audit data were to become compromised, forensic analysis and discovery of the true source of potentially malicious system activity would be impossible to achieve. To ensure the veracity of audit data, the information system and/or the application must protect audit information from unauthorized modification. This can be achieved through multiple methods, which will depend on system architecture and design. Some commonly employed methods include ensuring log files receive the proper file system permissions and limiting log data locations. Audit information includes all information (e.g., audit records, audit settings, and audit reports) needed to successfully audit information system activity. This does not apply to traffic logs generated on behalf of the device itself (management).

Check Content

Verify the firewall's fine-grained permissions are configured to prevent unauthorized modification of local log records.

If the firewall does not protect traffic log records from unauthorized modification while stored locally, this is a finding.

Fix Text

Validate the firewall includes a baseline cryptographic module that provides confidentiality and integrity services for authentication and for protecting communications with adjacent systems.