V-24382

CAT II (Medium)

On Classified Systems the Processor Resource/Systems Manager (PR/SM) must not allow access to system complex data.

Rule ID

SV-30057r2_rule

STIG

IBM Hardware Management Console (HMC) STIG

Version

V1R5

CCIs

CCI-000213

Discussion

Allowing unrestricted access to all Logical Partition data could result in the possibility of unauthorized access and updating of data. This could also impact the integrity of the processing environment.

Check Content

Have the Systems Administrator or Systems Programmer use the Hardware Management Console; to verify that the classified Logical Partition system data cannot be viewed by other Logical Partitions. <br /><br />Use the Security Definitions Panel to do this.  The Global Performance Data Control option must be turned off.<br /><br />NOTE:	The default is that the Global Performance Data Control option is turned off.<br /><br />If  the PR/SM allows access to system complex data then, this is a FINDING. <br />

Fix Text

Have the Systems Administrator or Systems Programmer use the Hardware Management Console, to verify that the classified Logical Partition system data cannot be viewed by other Logical Partitions. <br /><br />Use the Security Definitions Panel to do this.  The Global Performance Data Control option must be turned off.<br />