← Back to General Application (GAPP) Security Requirements Guide

V-288170

CAT II (Medium)

The application must enforce a 60-day maximum password lifetime restriction.

Rule ID

SV-288170r1252683_rule

STIG

General Application (GAPP) Security Requirements Guide

Version

V1R0.1

CCIs

CCI-004066

Discussion

Any password, no matter how complex, can eventually be cracked. Therefore, passwords need to be changed at specific intervals. One method of minimizing this risk is to use complex passwords and periodically change them. If the application does not limit the lifetime of passwords and force users to change their passwords, there is the risk that the system and/or application passwords could be compromised. This requirement does not include emergency administration accounts, which are meant for access to the application in case of failure. These accounts are not required to have maximum password lifetime restrictions.

Check Content

Navigate to the account configuration function within the application.

Verify the application is configured to enforce a 60-day maximum password lifetime restriction. Otherwise, this is a finding.

Fix Text

Navigate to the account configuration function within the application.

Configure a policy to enforce a 60-day maximum password lifetime restriction.