Rule ID
SV-285309r1258976_rule
Version
V1R1
CCIs
Time synchronization of system clocks is essential for the correct execution of many system services, including identification and authentication processes that involve certificates and time-of-day restrictions as part of access control. Denial of service or failure to deny expired credentials may result without properly synchronized clocks within and between systems and system components. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC. The granularity of time measurements refers to the degree of synchronization between system clocks and reference clocks, such as clocks synchronizing within hundreds of milliseconds or tens of milliseconds. Organizations may define different time granularities for system components. Time service can be critical to other security capabilities such as access control and identification and authentications depending on the nature of the mechanisms used to support the capabilities.
Verify the DNS server implementation is configured to synchronize system clocks within and between systems or system components. 1. Navigate to Infoblox Grid >> Grid Manager tab. 2. Click "NTP" service block. 3. Select the "Edit" drop-down from the toolbar on the right. 4. Select "Grid NTP Properties". 5. Validate the "Synchronize the Grid with these External NTP Servers" checkbox is selected. 6. Confirm there are external NTP time servers displayed. 7. Click "Save & Close". If external NTP servers are not configured, this is a finding.
Configure external NTP time servers: 1. From the Grid Manager GUI, Navigate to the Grid tab. 2. Click on the "NTP" service block. 3. Select the "Edit" drop-down from the toolbar on the right. 4. Select "Grid NTP Properties". 5. Select the "Synchronize the Grid with these External NTP Servers" checkbox. 6. Select the (+) icon and enter in an external NTP server by FQDN or IP Address. Note: If using FQDN, select "Resolve Name". 7. Click "Add". 8. Repeat steps 4–7 for additional external NTP servers. 9. Click "Save & Close". Note: It is recommended to configure at least three different external time sources to ensure reliability and a high degree of accuracy.