STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Ivanti MobileIron Sentry 9.x NDM Security Technical Implementation Guide

V-250992

CAT II (Medium)

MobileIron Sentry must enforce password complexity by requiring that at least one numeric character be used.

Rule ID

SV-250992r802198_rule

STIG

Ivanti MobileIron Sentry 9.x NDM Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-000194

Discussion

Use of a complex password helps to increase the time and resources required to compromise the password. Password complexity, or strength, is a measure of the effectiveness of a password in resisting attempts at guessing and brute-force attacks. Password complexity is one factor of several that determine how long it takes to crack a password. The more complex the password, the greater the number of possible combinations that need to be tested before the password is compromised. Multifactor authentication (MFA) is required for all administrative and user accounts on network devices, except for an account of last resort and (where applicable) a root account. Passwords should only be used when MFA using PKI is not available, and for the account of last resort and root account.

Check Content

Where passwords are used, confirm that MobileIron Sentry server enforces password complexity by requiring that at least one numeric character be used. This requirement may be verified by demonstration, configuration review, or validated test results.

If MobileIron Sentry server does not require that at least one numeric character be used in each password, this is a finding.

1. Log in to the System Manager of Sentry. 
2. Go to Security >> Identity Source >> Password. 
3. Verify "Numeric" is checked.

If "Numeric" is not checked, this is a finding.

Fix Text

Configure MobileIron Sentry server to enforce password complexity by requiring that at least one numeric character be used.

1. Log in to the System Manager of Sentry. 
2. Go to Security >> Password. 
3. Check "Numeric". 
4. Select "Apply".