STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Riverbed NetProfiler Security Technical Implementation Guide

V-256088

CAT II (Medium)

The Riverbed NetProfiler must be configured to authenticate SNMP messages using a FIPS-validated Keyed-Hash Message Authentication Code (HMAC).

Rule ID

SV-256088r961506_rule

STIG

Riverbed NetProfiler Security Technical Implementation Guide

Version

V2R1

CCIs

CCI-001967

Discussion

Without authenticating devices, unidentified or unknown devices may be introduced, thereby facilitating malicious activity. Bidirectional authentication provides stronger safeguards to validate the identity of other devices for connections that are of greater risk. A local connection is any connection with a device communicating without the use of a network. A network connection is any connection with a device that communicates through a network (e.g., local area or wide area network, internet). A remote connection is any connection with a device communicating through an external network (e.g., the internet). Because of the challenges of applying this requirement on a large scale, organizations are encouraged to apply the requirement only to those limited number (and type) of devices that truly need to support this capability.

Check Content

Go to Administration >> Appliance Security >> Security Compliance. 

Under "Operational Modes", verify "Strict Security Mode" is enabled. 

If it is not enabled, this is a finding.

Fix Text

Go to Administration >> Appliance Security >> Security Compliance. 

Under "Operational Modes", enable "Strict Security Mode".