V-258604

CAT II (Medium)

The ICS must be configured to record time stamps for audit records that can be mapped to Greenwich Mean Time (GMT).

Rule ID

SV-258604r961443_rule

STIG

Ivanti Connect Secure NDM Security Technical Implementation Guide

Version

V2R3

CCIs

CCI-001890

Discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

Check Content

In the ICS Web UI, navigate to System >> Status >> Dashboard.
1. Click the "Overview" tab.
2. Under "Appliance Details" and "System Date and Time", select "Edit".
3. Verify the "Time Zone" is set to "(GMT) Coordinated Universal Time".

If the ICS must be configured to record time stamps for audit records that can be mapped to GMT, this is a finding.

Fix Text

In the ICS Web UI, navigate to System >> Status >> Dashboard.
1. Click the "Overview" tab.
2. Under "Appliance Details" and "System Date and Time", select "Edit".
3. Select "(GMT) Coordinated Universal Time".