V-256704

CAT II (Medium)

ESX Agent Manager must disable the shutdown port.

Rule ID

SV-256704r888668_rule

STIG

VMware vSphere 7.0 vCenter Appliance EAM Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-002385

Discussion

An attacker has at least two reasons to stop a web server. The first is to cause a denial of service, and the second is to put in place changes the attacker made to the web server configuration. If the Tomcat shutdown port feature is enabled, a shutdown signal can be sent to the ESX Agent Manager through this port. To ensure availability, the shutdown port must be disabled.

Check Content

At the command prompt, run the following command:

# grep 'base.shutdown.port' /etc/vmware-eam/catalina.properties

Expected result:

base.shutdown.port=-1

If the output of the command does not match the expected result, this is a finding.

Fix Text

Navigate to and open:

/etc/vmware-eam/catalina.properties

Add or modify the setting "base.shutdown.port=-1" in the "catalina.properties" file.

Restart the service with the following command:

# vmon-cli --restart eam