STIGhubSTIGhub
STIGhub— A free STIG search and compliance tool·STIGs updated just now
Powered by Pylon·Privacy·Terms·Feedback·© 2026 Beacon Cloud Solutions, Inc.
← Back to Omnissa WS1 UEM Server Security Technical Implementation Guide

V-284260

CAT II (Medium)

The Omnissa WS1 UEM server must enforce the limit of three consecutive invalid logon attempts by a user during a 15-minute time period.

Rule ID

SV-284260r1224001_rule

STIG

Omnissa WS1 UEM Server Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-000044

Discussion

By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute forcing, is reduced. Limits are imposed by locking the account. Satisfies: FMT_SMF.1(2)b. Reference: PP-MDM-431028

Check Content

Authenticate to the Workspace ONE UEM console as an administrator. 
 
Navigate to Groups & Settings >> All Settings >> Admin >> Console Security >> Passwords. 
 
If "Maximum invalid login attempts" is not set to "3", this is a finding. 
 
Note: If this procedure is not seen on the console, the Cloud Service Provider (CSP) is managing the setting. Contact the CSP to review the required setting.

Fix Text

Authenticate to the Workspace ONE UEM console as an administrator. 
 
Navigate to Groups & Settings >> All Settings >> Admin >> Console Security >> Passwords. 
 
Next to "Maximum invalid login attempts", enter "3". Click "Save". 
 
Note: If this procedure is not seen on the console, the CSP is managing the setting. Contact the CSP to implement the required setting.