STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Ivanti MobileIron Core MDM Server Security Technical Implementation Guide

V-251774

CAT II (Medium)

The Ivanti MobileIron Core server must configured to lock administrator accounts after three unsuccessful login attempts.

Rule ID

SV-251774r810435_rule

STIG

Ivanti MobileIron Core MDM Server Security Technical Implementation Guide

Version

V1R1

CCIs

CCI-002238

Discussion

By limiting the number of failed login attempts, the risk of unauthorized system access via user password guessing, otherwise known as brute forcing, is reduced. Limits are imposed by locking the account. <br /><br />Satisfies:FMT_SMF.1(2)b <br />Reference:PP-MDM-431030

Check Content

Verify the Ivanti MobileIron Core server has been configured to lock administrator accounts after three unsuccessful login attempts.<br /><br />Log in to the Core Admin Console >> Settings >> Security >> Password Policy.<br />Verify "Number of Failed attempts" is set to "3".<br /><br />If the Ivanti MobileIron Core server does not lock administrator accounts after three unsuccessful login attempts, this is a finding.

Fix Text

Configure the Ivanti MobileIron Core server to lock administrator accounts after three unsuccessful login attempts.<br /><br />Log in to the Core Admin Console >> Settings >> Security >> Password Policy.<br />Set "Number of Failed attempts" to "3".