STIGhubSTIGhub
STIGsRMF ControlsCompare
STIGhub— A free STIG search and compliance tool·STIGs updated 3 days ago
Powered by Pylon·Privacy·Terms·© 2026 Beacon Cloud Solutions, Inc.
← Back to Application Security and Development Security Technical Implementation Guide

V-222391

CAT II (Medium)

Applications requiring user access authentication must provide a logoff capability for user initiated communication session.

Rule ID

SV-222391r961224_rule

STIG

Application Security and Development Security Technical Implementation Guide

Version

V6R4

CCIs

CCI-002363

Discussion

If a user cannot explicitly end an application session, the session may remain open and be exploited by an attacker. Applications providing user access must provide the ability for users to manually terminate their sessions and log off.

Check Content

If the application does not provide an interface for interactive user access, this is not applicable.

Log on to the application with a valid user account. Examine the user interface. Identify the command or link that provides the logoff function.

Activate the user logoff function.

Observe user interface and attempt to interact with the application.  Confirm user interaction with the application is no longer possible.

If the user session is not terminated or if the logoff function does not exist, this is a finding.

Fix Text

Design and configure the application to provide all users with the capability to manually terminate their application session.