V-256735

CAT II (Medium)

Lookup Service must disable the shutdown port.

Rule ID

SV-256735r888796_rule

STIG

VMware vSphere 7.0 vCenter Appliance Lookup Service Security Technical Implementation Guide

Version

V1R2

CCIs

CCI-002385

Discussion

An attacker has at least two reasons to stop a web server. The first is to cause a denial of service, and the second is to put in place changes the attacker made to the web server configuration. If the Tomcat shutdown port feature is enabled, a shutdown signal can be sent to the Lookup Service through this port. To ensure availability, the shutdown port must be disabled.

Check Content

At the command prompt, run the following commands:

# xmllint --xpath '/Server/@port' /usr/lib/vmware-lookupsvc/conf/server.xml

Expected result:

port="${base.shutdown.port}"

If the output does not match the expected result, this is a finding.

Fix Text

Navigate to and open:

/usr/lib/vmware-lookupsvc/conf/server.xml

Ensure the server port is set as follows:

<Server port="${base.shutdown.port}">

Restart the service with the following command:

# vmon-cli --restart lookupsvc